Mitsubishi M80 series Connection And Set Up Manual page 65

Hide thumbs Also See for M80 series:
Table of Contents

Advertisement

M800S/M80 Series Connection and Setup Manual
4 General Specifications
(7) EMG (External emergency stop input)
3
2
1
1
FG
2
I
EMG IN
3
O
+24V
<Cable side connector type>
Connector : 50-57-9403
Contact : 0016020103
Recommended manufacturer : MOLEX
(Note)
Use this when installing an emergency stop switch in the electric cabinet. Connect a terminator (G123
cable) when not using this connector.
(8) OPTH1 (High-speed optical servo communication 1st ch)
(9) OPTH2 (High-speed optical servo communication 2nd ch)
<Cable side connector type>
Connector : LGP-Z0007K
Recommended manufacturer : HONDA TSUSHIN KOGYO
(10) BAT (Battery I/F)
(11) CJ71 (Operation panel I/O unit I/F)
B
A
1 2 3 4
A1
I/O
TXRXD
A2
-
+5V
A3
-
-
A4
-
FG
<Cable side connector type>
Connector : 2-1318119-4
Contact : 1318107-1
Recommended manufacturer : Tyco Electronics
IB-1501269-F
B1
I/O
TXRXD*
B2
-
+3.3V
B3
-
0V
B4
-
0V
28