Inputting The Data From Nc - Mitsubishi M80 series Connection And Set Up Manual

Hide thumbs Also See for M80 series:
Table of Contents

Advertisement

M800S/M80 Series Connection and Setup Manual
25 Setting the Handy Terminal

25.2 Inputting the Data from NC

Create a download data (handy.cod) from a project data (*.p1t) created with "NC Designer HT", then download it to the
handy terminal.
(1) Start the customized data creation tool "NC Designer HT" to create a project data (*.p1t).
(2) Select [File] - [Writing download data] from the menu of "NC Designer HT" and save the data as download data
named "handy.cod" in the root directory of the SD card.
(3) Insert the SD card used in (2) into the control unit.
(4) Set the password currently set in the handy terminal to the parameter "#11011 Handy TERM. PW.".
(Note)
When you download for the first time or the password for the present custom data of the handy terminal is
invalid, leave the parameter blank.
(5) Turn OFF the NC and then connect the handy terminal to SIO connector on the control unit.
(6) Set the rotary switch on the control unit to "5".
Confirm that the DIP switches 1 and 2 are OFF. If they are ON, turn them OFF. (Normally, the DIP switches are
OFF.)
(a) LED
(b) Rotary switch
(7) Turn ON the NC again. (*)
(8) When the display of LED on the control unit becomes "En", turn OFF the NC.
(9) Remove the SD card and return the rotary switch.
(a)
(c) DIP switch 1
(d) DIP switch 2
425
(b)
(c)
(d)
IB-1501269-F

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

M800s series

Table of Contents