7 Connection of Control Unit

7.9 Connecting with Manual Pulse Generator

Connect the 5V power supply type manual pulse generator (2ch) to ENC connector of the control unit.
ENC
<Related items>
Cable drawing: "Cable: J026/J027 Cable"
Connector pin assignment: "General Specifications: Control Unit" (ENC connector)
When using the synchronous feed encoder and the manual pulse generator at the same time, the cables must be
prepared by the machine tool builder.
5V manual pulse generator
When connecting one 5V
manual pulse generator
J026
When connecting two 5V
manual pulse generators
J027
5V manual pulse generator
199
(Rear view)
NO.1
5V 0V A B
NO.1
NO.2
5V 0V A B