23 Setting the Tool Entry Prohibited Range
(2) Stored stroke limit IIB (When prohibited range is on inside)
A range except for that of the stored stroke limit I becomes the movement prohibited range.
IB-1501269-F
(C)
4
2
(A)
: Moveable range
: Prohibited range
(A): Set value for (-) side
(B): Set value for (+) side
(C): Prohibited range by stored stroke limit IIB
Point 3: "#8205 OT-CHECK-P" and
Point 4: "#8204 OT-CHECK-N" are set with the coordinate values in the basic machine
coordinate system.
Points 1 and 2 are the prohibited range set with stored stroke limit I.
3
(B)
410