9.6.1 Handle Numbers

There are two types of the handle numbers assignment: automatic assignment and arbitrary assignment.
[Automatic assignment]
Set all the parameters from "#1395 H1_pno (1st handle selection)" to "#1397 H3_pno (3rd handle selection)" to
"0000".
An example is shown below.
"ENC": Connector on control unit (two channels), "MPG": Connector on operation panel I/O unit (three channels)
Operation panel I/O unit
Used
Not used
Control unit
CJ71
ENC
[Arbitrary assignment]
Assign the handle I/F arbitrary according to the setting values of the parameters "#1395 H1_pno (1st handle
selection)" to "#1397 H3_pno (3rd handle selection)".
IB-1501269-F
1st handle
Group (a) ch1
Group (c) ch1
Operation panel I/O unit
MPG
CJ71
(5V/12V)
[ Group (b) ]
Manual Pulse Generator (ch1)
Manual Pulse Generator (ch2)
(5V)
218
Handle assignment
2nd handle
Group (a) ch2
Group (c) ch2
[ Group (a) ]
Manual Pulse Generator (ch1)
Manual Pulse Generator (ch2)
Manual Pulse Generator (ch3)
3rd handle
Group (a) ch3