Dog-Type - Mitsubishi M80 series Connection And Set Up Manual

Hide thumbs Also See for M80 series:
Table of Contents

Advertisement

M800S/M80 Series Connection and Setup Manual
22 Setting the Position Detection System

22.1.5 Dog-type

(1)
Preparations
Set the parameters on the
[Abs.Posit.Param.] screen.
(2)
Turn the power OFF and ON.
(Only when "#2049 type" has been reset.)
The following are the operations on [Absolute position setting screen].(Select [Mainte] -> [To Abs pos])
(3)
Select the axis set to type 3 on the
[Abs.Posit.Param.] screen.
Select the menu [Axis select], enter
the axis name (#1022 axname2
(display axis name)) in the input area
and then press [INPUT].
(4)
Execute the manual or automatic dog-
type zero point return.
(5)
The axis arrives at the zero point.
The zero point initialization is now complete. After initializing all axes, turn the power OFF and ON.
(Note 1) If the dog-type reference position return is interrupted by resetting, the previous state ("Complete" or
"Illegality") will display in the [State] column.
(Note 2) With dog-type reference position return, reference position return can be executed again even if the [State] is
"Complete".
#2049 type (absolute position detection type) = 3 (dog-type)
State: [Zero-P. Rel.]
Machine position: Current machine position
State: [Complete]
Machine position: 0.000
393