Mitsubishi M80 series Connection And Set Up Manual page 126

Hide thumbs Also See for M80 series:
Table of Contents

Advertisement

M800S/M80 Series Connection and Setup Manual
4 General Specifications
(a) Outline of digital signal output circuit
Use within the specification ranges shown below.
Output circuit
Source output
Output conditions
Insulation method
Rated load voltage
Max. output current
Output delay time
(Note 1) When using an inductive load such as a relay, always connect a diode (voltage resistance
Source output
24VDC
CJ32/CJ34
Load
Y00
Y2F
100V or more, twice or more the load current) in parallel to the load.
24VDC
Inductive load
Y
Diode
Control
circuit
Non-insulation
24VDC
0.2A/point
3.2A or less in the whole unit
40μs
Control
circuit
89
IB-1501269-F