20.4 Setting the Communication with GX Developer

(1) Perform the following operations with GX Developer to start the setup screen.
[Online] -> [Transfer setup...]
(2) Set the following items in order.
PC side I/F
Network No.
Station No.
Protocol
PLC side I/F
Computer type
Station No.
IP address
Routing parameter transfer method
Other station
Time out (Sec.)
Retry times
Network route
Access to the Ethernet module set by PC side I/F
(Note 1) Double click the "Ethernet board" selection filed to display the setting item.
(Note 2) Double click the "Ethernet module" selection filed to display the setting item.
(Note 3)Double click the "Other station (Co-existence network)" selection field to display the setting item.
(Note 4)Double click "Ethernet" to display the setting item.
■ SW8D5C-GPPW setting screen
(3) Press the "Connection test" button after completing the setting.
If the connection has succeeded, the message "Successfully connected with the Q26UDHCPU." will be displayed
and the multiple CPU connection status will be displayed at the bottom of the message. This display indicates
connection status for each project.
Setting item
Ethernet board
1
1
TCP
Ethernet module
QJ71E71
1
IP address of CNC
Automatic transfer method
Other station (Single network)
Arbitrary time (about 10 seconds or more)
0
Ethernet
Setting content
365
Remarks
(Note 1)
(Note 1)
(Note 1)
(Note 2)
(Note 2)
(Note 2)
(Note 2)
(Note 3)
(Note 3)
(Note 4)
IB-1501269-F