M800S/M80 Series Connection and Setup Manual
17 Setting the Hardware
MDS-EJ/EJH-Vx
Connect the battery connector to the connector BAT of the drive unit.
Installation
Replacing the built-in battery
MR-BAT6V1SET that reached the end of the life can be reused
by replacing the MR-BAT6V1 battery.
Cover
MR-BAT6V1
IB-1501269-F
Insert the plug to BAT
after installing the battery.
Open the cover while pushing the locking part.
Locking part
Replace the built-in battery with a new battery
for MR-BAT6V1.
Close the cover by pushing until it is fixed
with the tab of the locking part.
Tab
Removal
328
Pull out the connector while
pushing the unlocking lever.
Slide the case of
MR-BAT6V1SET toward you
while pushing the unlocking lever.