M800S/M80 Series Connection and Setup Manual
15 Cable
15.3.15 SH21 Cable
Max. cable length: 30m
Application: Power supply communication cable
Power backup unit communication cable
[CN4,CN9]
Plug: 10120-3000PE
Shell: 10320-52F0-008
Recommended manufacturer: 3M
(Note 1) Fold the cable shield over the sheath, and wrap copper foil tape over it. Connect the wound copper foil
tape to GND plate of the connector.
(Note 2) When using the jackscrew M2.6-type 10320-52A0-008 for the shell, do not fasten the screws too tightly
otherwise the connector and the PCB may be damaged.
(Manufacturer recommended tightening torque: 0.20±0.05N·m)
IB-1501269-F
CN4, CN9
0V
1
0V
11
SVTXD
2
SVTXD*
12
SVALM
3
SVALM*
13
SVRXD
4
SVRXD4
14
0V
5
0V
15
6
16
SVEMG
7
SVEMG*
17
8
18
9
19
+5V
10
20
FG
Wire material: UL20276 AWG28×10P
Recommended manufacturer:
Toyokuni Electric Cable
310
1
0V
11
0V
2
SVTXD
12
SVTXD*
3
SVALM
13
SVALM*
4
SVRXD
14
SVRXD4
5
0V
15
0V
6
16
7
SVEMG
17
SVEMG*
8
18
9
19
10
+5V
20
FG
Plug: 10120-3000PE
Shell: 10320-52F0-008
Recommended manufacturer: 3M