J020/J021/J022 Cable - Mitsubishi M80 series Connection And Set Up Manual

Hide thumbs Also See for M80 series:
Table of Contents

Advertisement

M800S/M80 Series Connection and Setup Manual
15 Cable

15.2.7 J020/J021/J022 Cable

Max. cable length: 50m
Application: Manual Pulse Generator cable (12V)
[MPG]
Connector : 10120-3000PE
Case : 10320-52F0-008
Recommended manufacturer : 3M
Cable name
J020 cable
J021 cable
J022 cable
Unconnectable to control unit side
(Note 1) Fold the cable shield over the sheath, and wrap copper foil tape over it. Connect the wound copper foil
tape to GND plate of the connector.
(Note 2) The cables for 1ch and 2ch are compatible with F320 or F321 cable of the conventional model.
(Note 3) When using the jackscrew M2.6-type 10320-52A0-008 for the shell, do not fasten the screws too tightly
otherwise the connector and the PCB may be damaged.
(Manufacturer recommended tightening torque: 0.20±0.05N·m)
MPG
MPG
4
HA1A
HA1B
14
6
+12V
1
0V
HA2A
3
13
HA2B
16
+12V
0V
11
2
HA3A
HA3B
12
9
+12V
5
0V
FG
Wire material :
UL2464 U-TKVVBS AWG24 × 6P
Recommended manufacturer :
Tachii Electric Wire
1ch
2ch
3ch
○ : Usable channel
HA1
HB1
12V1
0V1
HA2
HB2
12V2
0V2
HA3
HB3
12V3
0V3
[1ch][2ch][3ch]
Crimp terminal : R1.25-3 × 12
Recommended manufacturer : JST
281
1ch
2ch
3ch
IB-1501269-F

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

M800s series

Table of Contents