M800S/M80 Series Connection and Setup Manual
4 General Specifications
Dimension and names of parts
255
90
No.
Name
(1)
LCD
(2)
SW1
(3)
-
(4)
SW2
(5)
SW4
(6)
SW6
(Note)
Do not press multiple switches simultaneously: When three or more switches are pressed simultaneously,
unpressed switches are also detected as pressed ones.
133
46.7
(1)
(2)
(3)
Function/ Specification
Monochrome display with
backlight
192(W) × 64(H) dots
Emergency stop switch
Contact rating/ Contact: 24VDC,
1A
Contact configuration: 2b contacts
(IDEC Corporation: HA1E-
V2S2VR)
Membrane switch (Note)
Enable switch
Contact rating/ Contact: 24VDC,
50mA
Contact configuration: 3 position
contact × 2
(OFF-ON-OFF)
(IDEC Corporation: HE3B-M2)
Manual pulse generator
Output: Open collector
4.7kΩ pull-up resistor is
connected. (TOKYO
SOKUTEIKIZAI CO., LTD:
RE19PH50C16RR)
Selector switch
(10)
15
(6)
(5)
(4)
(7)
No.
Name
(7)
HOST
(8)
-
(9)
-
(10) -
(11) -
141
51
(11)
38
11.5
(9)
(8)
Function/ Specification
Host interface connector
(DDK: 17JE-23250-02(D8A6))
Host interface cable
(5m)
Simplified hand strap
(IDEC Corporation: HG9Z-PS1)
Panel hanging fitting
(IDEC Corporation: HG9Z-TK1)
Serial number plate
IB-1501269-F

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

M800s series