136 Configuring a 2350 Switch for a Branch Office

Accessing the CLI

Initial configuration of the WSS requires a connection to the switch's CLI through the serial console port.
To connect a PC to the serial console port:
1
Insert the serial cable into the PC port.
2
Insert the other end of the cable into the serial console port on the 2350 switch.
3
Start a standard VT100 terminal emulation application on the PC, and configure the following
modem settings:
9600 bps
8 bits
1 stop
No parity
Hardware flow control off or disabled
4
Open a connection on a serial port.
5
Press Enter three times to display a command prompt:
2350>
Note.
number and also contains the last three octets of the switch's MAC address. For
example, the default command prompt on an 2350 switch with MAC address
00:0B:0E:00:04:0B is 2370-00040B>.
320656-A
The default command prompt on your WSS shows your switch's model