Model:
MET-C1b
Subject:
SC866 cannot be resolved after replacing controller
board
From:
1st Tech Service Sect., MFP/P Tech Service Dept.
Classification:
SYMPTOM
SC866 occurs and the SC cannot be resolved after replacing the controller board.
Affected models: Met-C1abcde/yz (D146 / D147 / D148 / D149 / D150 / D176 / D177)
CAUSE
Memory corruption
SOLUTION
If the symptom occurs, replace the RAM-DIMM (p/n: 19070159).