Download Print this page

Ricoh MP C4503 Technical Bulletin page 461

Model: met-c1ab, met-c1ab_sop
Hide thumbs Also See for MP C4503:

Advertisement

Reissued: 07-Jul-15
Model:
Z-C2_SOP/ OR-C2_SOP/ Cor-C1_SOP/
MET-C1ab_SOP/ MET-C1cde_SOP/MET-C1yz_SOP
RTB Reissue
The items in bold italics have been corrected or added.
Subject:
Firmware Release Note: IDCARDCOPY
From:
Connectivity Support Sect., MFP/P Tech Service Dept.
Classification:
Important Information about Normal/Smart Panel
 When updating machine firmware, make sure NOT to install Smart Panel supported
firmware on a machine with a normal operation panel (and vice-versa). If you do, the
machine may not function as designed and product warranty may not apply.
 To avoid this, when updating the firmware, make sure that the numbers next to
"NEW" and "ROM" are the same on the operation panel.
 If you install the wrong firmware, repeat the update procedure and check the
numbers mentioned above.
This RTB has been issued to announce the firmware release information for the
IDCARDCOPY.
Version
Program No.
1.2
D1505531A
1.1
D1505531A
Note: Definition of Availability of RFU via @Remote
"Available" The firmware can be updated via RFU or SD card.
"Not available": The firmware can only be updated via SD card.
Version
1.2
Symptom corrected:
1.
When ID Card Copy is opened, after entering and then recovering from
energy-saving mode, restarting ID Card Copy, navigating to the home
screen, and then reopening ID Card Copy, it takes approximately 30
seconds to display the first screen of the application.
2.
When the "Stop" key is pressed after scanning only one side of a
document and then "Continue Printing" is selected, the following
problems occur:
- An error message for Quick Copy will be displayed above the
echnical
T
Troubleshooting
Mechanical
Paper path
Product Safety
Firmware Updates
Modified Points or Symptom Corrected
screen.
ulletin
B
Date:
Prepared by:
Part information
Electrical
Transmit/receive
Other (Firmware)
Effective Date
June 2015 production
Initial release
PAGE: 1/2
No
27-Mar-15
.: RD193047b
Y. Fukuzaki
Action required
Service manual revision
Retrofit information
Tier 2
Availability of RFU
Not Available
Not Available

Hide quick links:

Advertisement

loading