Reissued: 10-Jun-15
Model:
MET-C1b
SP settings
1.
Set the following SP modes as shown:
Set SP5-748-101 [Op Type Action Setting] bit 0 to a value of 1.
Set SP5-748-201 [Smart Operation Panel Connect Setting] to a value of 1.
2.
Turn the machine main power off.
Installation
1.
Remove the normal operation panel.
2.
Attach the Smart Operation Panel Type M3.
3.
Turn the machine main power ON.
4.
Set the following SP modes as shown:
Set SP5-752-001 [Copy FlairAPI Function Setting] bit 0 to a value of 1.
Set Scanner SP1-041-001 [Scanner FlairAPI Function Setting] bit 0 to a value of 1.
5.
If the fax option is installed:
Set Fax SP3-301-001 [FAX FlairAPI Function Setting] bit 0 to a value of 1.
6.
Turn the machine main power off/on.
Note: If the panel has been connected normally, the default setting icons will appear.