11 Position of the hook and needle

11.1 Setting the hook side clearance

Order
First check the following settings:
• A straight and undamaged needle has to be inserted
• Needle bar linkage ( 10 Aligning the needle bar linkage, page 33)
• Loop stroke position ( 11.2 Setting the loop stroke position, page 38)
Correct setting
Machine locked in place at position 1 ( page 16).
 Maximum 0.1 mm distance between the hook tip and the groove for the
Cover
• Tilt the upper section ( 3.3.1 Access to the machine bottom section,
• Throat plate slide ( 3.3.5 Opening and closing the throat plate slide,
36
WARNING
Risk of injury.
Crushing injuries from moving parts.
Switch off the sewing machine before checking and
setting the hook side clearance.
( Operating manual section, Inserting and replacing the needle)
ATTENTION
Damage to the machine, needle breakage, or thread damage due to
an incorrect clearance between the needle and hook tip
Check the distance to the hook tip after inserting a new needle with a
different size.
Reset distance if necessary.
needle.
page 10)
page 13)
Position of the hook and needle