Faults caused by an incorrect needle bar height
• Damage to the hook tip
• Jamming of the needle thread
• Missing stitches
• Thread breakage
• Needle breakage
Cover
• Head cover ( 3.3.3 Removing and fitting the head cover, page 12)
Fig. 31: Setting the needle bar height
Setting steps
1. Lock the machine in place at position 1 ( page 16).
2. Position the stitch length adjusting wheel to 0.
3. Loosen the screw (2) for the needle bar (1).
4. Move the height of the needle bar (1) such that the hook tip (4) is in the
5. Tighten the screw (2) for the needle bar (1).
6. Remove the lock ( page 17).
Order
Then check the following setting:
• Position of the needle guard ( 11.3 Adjusting the needle guard,
42
(1) - Needle bar
(2) - Screw
lower third of the groove for the needle.
Do not twist the needle to the side in doing so. The groove (3) must
face towards the hook.
page 40)
Position of the hook and needle
(3) - Needle groove
(4) - Hook tip