Correct setting
The distance between the raised sewing feet and the throat plate is preset
to 20 mm on delivery.
Cover
Arm cover ( 3.3.2 Removing and fitting the arm cover, page 11)
Fig. 40: Setting the sewing foot lifting height
Setting steps
1. Loosen the adjusting wheel for the sewing foot pressure:
2. Loosen the setscrews (1).
3. Turn the lever (1) to set the distance between the raised sewing feet
4. Tighten the setscrews (1).
50
(1) - Setscrew
(2) - Lever
and the throat plate:
• To raise the sewing feet to a lesser height: Turn it clockwise
• To raise the sewing feet higher: Turn it counterclockwise