Upgrading The Firmware - Symmetricom TimeProvider 5000 User Manual

Ieee 1588 grand master clock / ntp server
Hide thumbs Also See for TimeProvider 5000:
Table of Contents

Advertisement

Type
set configuration restore imc-from-ioc1
Warning: To avoid possible electrostatic damage to the module or
panel, place it in a static-free bag or on a static-free surface.

Upgrading the Firmware

You can upgrade the firmware in the IMC, IOC or redundant IOCs, or expansion
shelves using CLI commands and software available from Symmetricom. Only
users with Admin level access can execute the "upgrade" command. The command
places the IMC in the firmware download mode and prevents all other sessions from
making changes to the configuration. During the upgrade process, no new sessions
are allowed. Refer to
upgrade, on page 255 for details on the upgrade process.
The upgrade procedure to be used to upgrade the TP 5000 is based on the
configuration of the TP 5000, firmware version from which the unit is being
upgraded, and whether loss of outputs is acceptable.
TP5000 with a single IOC module upgrading from 1.1.8 or 1.2.3 release to 2.0.4,
please follow the procedure
TP5000 with Redundant IOC modules upgrading from 1.1.8 release to 2.0.4,
please follow the step-by-step procedure
v1.1.8 - No Loss of Outputs
TP5000 with Redundant IOC modules upgrading from 1.2.3 release to 2.0.4,
please follow the step-by-step procedure
v1.2.3 - No Loss of Outputs
All systems: When upgrading from released versions prior to 1.1.8, the upgrade
process must be performed in two steps. The TP5000 must be upgraded to 1.1.8
first and then upgraded to 2.0.4 using the relevant procedure below. See page
258 in Rev. D of the TimeProvider User's Guide (098-00028-000 Rev. D) for the
procedure "Upgrading from TP5000 v1.0 to v1.1 or Higher".
Upon receipt of any new/repaired equipment, perform the relevant software
upgrade procedure below prior to putting the shelf into service.
098-00028-000 Revision F – May, 2012
Chapter 3, CLI Commands and SNMP
TP5000 Upgrade - Loss of Outputs
below.
below.
Chapter 6 Maintenance and Troubleshooting
and press Enter..
and the command
TP5000 with Redundant IOC Modules
TP5000 with Redundant IOC Modules
TimeProvider 5000 User's Guide 389
Upgrading the Firmware