To provision the output behavior during the fast-track state:
set output fast-track {port1|port2|port3|port4}
{on|squelch|ais}
To enable the output test mode:
set output-test-mode {port1|port2|port3|port4}
[t1pulse|disable]
Example 1:
To Enable output Port 2:
tp5000> set output state port2 enable
Example 2:
To set the frame type to 2048 kHz for output Port 1:
tp5000> set output frametype port1 freq2048khz
Example 3:
To Enable CRC for output Port 3:
tp5000> set output crc port3 enable
Example 4:
To Enable SSM for output Port 2:
tp5000> set output ssm port2 enable
Example 5:
To provision the SSM Bit value for E1 signals to 6 for output port2:
tp5000> set output ssm-bit port2 6
Example 6:
To provision the output behavior to squelch during the warm-up state for port2:
tp5000> set output warm-up port2 squelch
Example 7:
To provision the output behavior to squelch during the free-run state for port2:
tp5000> set output free-run port2 squelch