Chapter 6 Maintenance and Troubleshooting

Repairing the TimeProvider 5000

Table 6-5. LED Conditions for the Expansion Shelf (Continued)
Indicator
Label
DTI/ETH
MGMT
Expansion
shelf Port
LEDs on the
Ethernet
connector
GPS Status
REF
GPS engine
status indicator
Repairing the TimeProvider 5000
Repairing the TimeProvider 5000 is limited to replacing modules. Refer to
With
Modules, on page 67, for information on how to properly handle modules to
prevent electrostatic or physical damage.
Each power module in the TimeProvider contains a 3A fuse, but these fuses are not
field-replaceable. There are no field-serviceable fuses in the TimeProvider 5000. If a
fuse blows in a TimeProvider 5000, the unit must be returned to the factory for
repair.
384 TimeProvider 5000 User's Guide
Description
Green - Activity on link to TP 5000
IMC DTI/ETH expansion
port
Green Flash - Link to TP 5000
IMC DTI/ETH expansion
port has been
established
Off - Link to TP 5000 IMC
DTI/ETH expansion port
has not been established
Green - Exp clock is in fast
tracking or normal
tracking
Amber - Expansion clock is in
holdover or acquire
mode
Amber Flash - Expansion clock is
in warm-up
Corrective Action
n/a
n/a
Check cable and connections
n/a
Use "show alarm" command to
view alarm IDs and descriptions.
Table A-1
Appendix A,
See
in
System Messages
for corrective
actions.
Use "show GPS" command to see
detected satellites and their signal
levels.