show bridge-time
Displays the bridging time that is used to allow the frequency servo to coast through
short periods when the system does not have qualified reference. The bridging time
is in seconds.
Command Syntax:
show bridge-time
Example:
tp5000> show bridge-time
Response:
Bridging Time
Remarks: If the system has not qualified a ToD Source (frequency reference) within
the specified bridging time the system transitions into holdover mode of operation.
Level :
User, Config, and Admin
set bridge-time
Provisions the amount of time, in seconds, the system remains in bridging mode
before transitioning into the holdover mode of operation.
Note: Updates to the bridging-time value are only used at the start of
the next bridging event. Any changes to this value while the unit is in
bridging mode will not be implemented until the next bridging event.
Command Syntax:
set bridge-time <bridging-time>
Range:
100 to 100000 seconds
Default:
900 seconds
Example:
tp5000> set bridge-time 1000
Level :
Config and Admin only
098-00028-000 Revision F – May, 2012
TimeProvider 5000 CLI Command Set
- 900
TimeProvider 5000 User's Guide 109