Table 6. System pulse LEDs (continued)
PCI riser-card LEDs
Use this information to view PCI riser-card LEDs.
The following illustration shows the location of the PCI riser-card LEDs.
u8693_pci_risers
Figure 20. PCI riser-card LEDs

Event logs

Error codes and messages displayed in POST event log, system-event log, integrated management module
(IMM2.1) event log, and DSA event log.
• POST event log: This log contains the most recent error codes and messages that were generated
during POST. You can view the contents of the POST event log from the Setup Utility (see "Starting the
Setup Utility" on page 31). For more information about POST error codes, see Appendix B "UEFI/POST
diagnostic codes" on page 819.
• System-event log: This log contains POST and system management interrupt (SMI) events and all
events that are generated by the baseboard management controller that is embedded in the integrated
management module (IMM). You can view the contents of the system-event log through the Setup Utility
and through the Dynamic System Analysis (DSA) program (as IPMI event log).
The system-event log is limited in size. When it is full, new entries will not overwrite existing entries;
therefore, you must periodically clear the system-event log through the Setup Utility. When you are
troubleshooting an error, you might have to save and then clear the system-event log to make the most
recent events available for analysis. For more information about the system-event log, see Appendix A
"Integrated management module 2.1 (IMM2.1) error messages" on page 179.
Messages are listed on the left side of the screen, and details about the selected message are displayed
on the right side of the screen. To move from one entry to the next, use the Up Arrow (-) and Down
Arrow (¯) keys.
1 Hz), this indicates that IMM2.1 is fully
operational. You can now press the
power-control button to power on the
server.
4. If this LED does not blink within 30 seconds
of connecting a power source to the server,
(trained technician only) replace the system
board.
1U PCIe Riser 1
assembly (1x low
profile; x16)
1U PCIe Riser 2
assembly (1x
full-height half-length;
x16 and 1x low
profile; x8 or x16)
Chapter 3
57
.
Troubleshooting