Lenovo HX1310 Installation And Service Manual page 438

Converged systems converged hx series
Table of Contents

Advertisement

Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0392
User Response
If there is no GPU/storage tray installed in the system, then the log event is a normal condition. If
there is a GPU/storage tray installed in the system, then check the following two portions:
1. PDB (Power Distribution Board) cable is correctly connected from riser card to PDB.
2. Replace another PDB cable.
• 806f0207-0301ffff : [ProcessorElementName] has Failed with FRB1/BIST condition. (CPU 1)
This message is for the use case when an implementation has detected a Processor Failed - FRB1/BIST
condition.
May also be shown as 806f02070301ffff or 0x806f02070301ffff
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - CPU
SNMP Trap ID
40
CIM Information
Prefix: PLAT ID: 0044
User Response
1. Make sure that the latest levels of firmware and device drivers are installed for all adapters and
standard devices, such as Ethernet, SCSI, and SAS. Important: Some cluster solutions require
specific code levels or coordinated code updates. If the device is part of a cluster solution, verify
that the latest level of code is supported for the cluster solution before you update the code.
2. Update the firmware (UEFI and IMM) to the latest level (Updating the firmware).
3. Run the DSA program.
4. Reseat the adapter.
5. Replace the adapter.