2. Make sure that the scalability cable connections are as per specification.
3. Make sure that DSA and BIOS/uEFI are at the latest level.
4. If the problem remains, contact your technical-service representative.
Related links
–
IBM Support website
–
Latest level of DSA
–
Latest level of BMC/IMM
•
401-901-001 : EXA Port Ping Test Failed
EXA Port Ping Test Failed.
Recoverable
No
Severity
Error
Serviceable
Yes
Automatically notify support
No
User Response
Complete the following steps:
1. Remove power cables, wait for 45 seconds, reconnect and rerun the test.
2. Make sure that the scalability cable connections are as per specification.
3. Check scalability cables for loose connections.
4. Replace the scalability cable(s) for specified port(s).
5. If the problem remains, contact your technical-service representative.
Related links
–
IBM Support website
–
Latest level of DSA
–
Latest level of BMC/IMM
DSA hard drive test results
The following messages can result when you run the hard drive test.
Test results for the DSA hard drive test
The following messages can result when you run the DSA hard drive test.
•
217-000-000 : HDD Test Passed
860