4. (Trained technician only) Replace system board.
RR PCI3 Amb Temp :
• 80010701-1301ffff : Numeric sensor [NumericSensorElementName] going high (upper non-critical)
has asserted. (PSU 1 Amb Temp)
This message is for the use case when an implementation has detected an Upper Non-critical sensor
going high has asserted.
May also be shown as 800107011301ffff or 0x800107011301ffff
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
Warning - Temperature
SNMP Trap ID
12
CIM Information
Prefix: PLAT ID: 0490
User Response
1. Reduce the ambient temperature.
2. Ensure the air baffle is installed correctly.
3. Check the server airflow. Make sure that nothing is blocking the air from coming into or
preventing the air from exiting the server.
• 80010701-1302ffff : Numeric sensor [NumericSensorElementName] going high (upper non-critical)
has asserted. (PSU 2 Amb Temp)
This message is for the use case when an implementation has detected an Upper Non-critical sensor
going high has asserted.
May also be shown as 800107011302ffff or 0x800107011302ffff
Severity
Warning
Serviceable
Yes
Automatically notify support
No
300
HX1310, HX2310-E, HX3310, HX3310-F Installation and Service Guide