Lenovo HX1310 Installation And Service Manual page 840

Converged systems converged hx series
Table of Contents

Advertisement

Complete the following steps:
1. Information only; no action is required.
• I.580A4 Memory population change detected. DIMM Population Change Detected
Explanation:
Severity
Info
User Response
Complete the following steps:
1. If you have added or removed DIMMs to the system, and no additional errors were detected,
then please ignore this message.
2. Check system event log for uncorrected DIMM failures and replace those DIMMs.
• I.580A5 Mirror Fail-over complete. DIMM number [arg1] has failed over to to the mirrored copy.
DIMM Mirror Fail-over Detected
Explanation:
Severity
Info
User Response
Complete the following steps:
1. Check the system-event log for uncorrected DIMM failures and replace those DIMMs.
• I.580A6 Memory spare copy has completed successfully. Spare Copy Complete
Explanation:
Severity
Info
User Response
Complete the following steps:
1. If you have added or removed DIMMs to the system, and no additional errors were detected,
then please ignore this message.
2. Check system event log for uncorrected DIMM failures and replace those DIMMs.
• S.1100B CATERR(IERR) has asserted on processor [arg1]. Processor CATERR(IERR) has asserted
Explanation:
Severity
Error
User Response
Complete the following steps:
826
HX1310, HX2310-E, HX3310, HX3310-F Installation and Service Guide

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hx3310Hx2310-eHx3310-f

Table of Contents