11.1.22 Sudden stop deceleration time [BFM #14102, BFM #14302]

Set the time to reach 0 speed from the maximum speed at sudden stop. (Ver.1.20 or later)
BFM Number
X-axis
Y-axis
BFM #14102
BFM #14302
POINT
• The sudden stop deceleration time becomes 1 ms when set at 0 ms or less, and becomes 5000 ms when
set at 5001 ms or more.

11.1.23 Sudden stop interpolation time constant [BFM #14104, BFM #14304]

Set the time to reach 0 speed from the operation speed at sudden stop (interpolation operation).
(Ver.1.20 or later)
BFM Number
X-axis
Y-axis
BFM #14104
BFM #14304
POINT
• The sudden stop interpolation time constant becomes 1 ms when set at 0 ms or less, and becomes 5000
ms when set at 5001 ms or more.
11.1.24 Positioning completion signal output waiting time
[BFM #14106, BFM #14306]
Set the time after positioning is completed until the positioning completion flag turns ON. (Ver.1.20 or later)
→ For details on the positioning completion signal output waiting time, refer to Section 7.5
BFM Number
X-axis
Y-axis
BFM #14106
BFM #14306
POINT
• When the positioning operation time is shorter than a PLC scan, the sequence program can only detect the
positioning completion signal if the positioning completion signal output waiting time is set to a time longer
than the scan time.
• Becomes 5000 ms when set at 5001 ms or more.
• If positioning is completed and an error occurs during the positioning completion signal output waiting time,
the positioning completion signal remains OFF.
• The setting of the positioning completion signal output waiting time is invalid during table operation.
→ For details on the sudden stop deceleration time, refer to Section 7.5
Setting range: 1 to 5000 ms
→ For details on the sudden stop interpolation time constant, refer to Section 7.5
Setting range: 1 to 5000 ms
Setting range: 0 to 5000 ms
11 Buffer Memory (Parameters & Monitored Data)
11.1 Positioning Parameters
Description
Description
Description
11
Default
12
K200
13
A
Default
K100
B
Default
K0