3U
11.3.27 Regenerative load ratio [BFM #65, BFM #165]
The regenerative load ratio power to the maximum regenerative power is stored in percentage.
With regenerative brake option, the regenerative power ratio to the allowable capacity is stored.
BFM Number
X-axis
BFM #65
BFM #165
11.3.28 Effective load torque [BFM #66, BFM #166]
The continuous effective load torque is stored.
This parameter stores the average value of the load ratio to the rated torque (100%) from the past 15
seconds.
BFM Number
X-axis
BFM #66
BFM #166
11.3.29 Peak torque ratio [BFM #67, BFM #167]
The maximum torque during operations is stored.
This parameter stores the peak value to the rated torque (100%) from the past 15 seconds.
BFM Number
X-axis
BFM #67
BFM #167
11.3.30 Servo warning code [BFM #68, BFM #168]
Warnings detected by the servo amplifier are stored.
Clear the cause of the warning.
11.3.31 Motor feedback position [BFM #71, #70, BFM #171, #170]
Motor feedback positions are stored.
BFM Number
X-axis
BFM #71,#70
144
Y-axis
Regenerative load ratio (%)
Y-axis
Effective load torque (%)
Y-axis
Peak torque ratio (%)
→ For details on the warnings, refer to the manual of the connected servo amplifier
Y-axis
BFM #171,#170
Motor feedback position (PLS)
11 Buffer Memory (Parameters & Monitored Data)
Description
Description
Description
→ For details on the warning codes, refer to Subsection 13.2.4
Description
11.3 Monitor Data
Value Format
Default
Decimal
-
Value Format
Default
Decimal
-
Value Format
Default
Decimal
-
Value Format
Default
Decimal
-