Related parameters, control data and monitor data

Item
Positioning parameters
Operation
Ring counter setting
parameter 2
(Ver.1.10 or later)
Maximum speed
Torque limit setting
FLS/RLS signal
selection
External signal
selection
FLS/RLS signal
logic
Ring counter upper limit value
(Ver.1.10 or later)
Control data
Torque output value
Forward rotation
limit (LSF)
Operation
command 1
Reverse rotation
limit (LSR)
Pulse generator magnification
(numerator)
Pulse generator magnification
(denominator)
Pulse generator magnification
response (Ver.1.10 or later)
Pulse generator magnification input
selection (Ver.1.10 or later)
Monitor data
Current address (user)
Current address (pulse)
Manual pulse generator current input
value
Manual pulse generator input
frequency
*1.
For user units, refer to the following.
BFM number
X-axis
Y-axis
BFM #14002 b3
BFM #14202 b3
BFM #14009,#14008
BFM #14209,#14208
BFM #14038
BFM #14238
BFM #14044 b0
BFM #14244 b0
BFM #14044 b8
BFM #14244 b8
BFM #14101, #14100 BFM #14301, #14300 Setting range : 1 to 2,147,483,646 (user unit)
BFM #510
BFM #610
BFM #518 b2
BFM #618 b2
BFM #518 b3
BFM #618 b3
BFM #525,#524
BFM #625,#624
BFM #527,#526
BFM #627,#626
BFM #528
BFM #628
BFM #529
BFM #1,#0
BFM #101,#100
BFM #3,#2
BFM #103,#102
BFM #13,#12
BFM #113,#112
BFM #15,#14
BFM #115,#114
8 Manual Control
8.3 Manual pulse generator operation
Description
OFF: Disables the ring operation.
ON : Enables the ring operation.
Setting range:1 to 2,147,483,647(user units)
Setting range : 1 to 10000 (×0.1%)
OFF: The FLS/RLS signal of the servo amplifier is
not used.
ON : The FLS/RLS signal of the servo amplifier is
used.
OFF: The NO contact the FLS/RLS signal logic of the
servo amplifier.
ON: The NC contact for the FLS/RLS signal logic of
the servo amplifier.
Setting range : 1 to 10000 (×0.1%)
In an MPG operation, the work piece stops
immediately with this bit ON during forward rotation
output.
In an MPG operation, the work piece stops
immediately with this bit ON during reverse rotation
output.
Specify the magnification for input pulses.
Setting range: 1 to 1,000,000
Specify the dividing rate for input pulses.
Setting range: 1 to 1,000,000
Sets the MPG response
Setting range: 1 to 32767
Sets the MPG input selection
0: X input - X opr / Y input - Y opr
1: X input / Y opr
2: X input - X and Y opr
-2,147,483,648 to 2,147,483,647
*1
(user unit)
-2,147,483,648 to 2,147,483,647PLS
-2,147,483,648 to 2,147,483,647PLS
The sign is positive (+) for an increasing count, while
the sign is negative (-) for a decreasing count.
-100,000 to 100,000Hz
→ Refer to Section 7.9
1
2
*1
3
*1
4
5
6
7
8
9
10