Ring Counter Setting (Ver.1.10 Or Later) - Mitsubishi FX3U-20SSC-H User Manual

Hide thumbs Also See for FX3U-20SSC-H:
Table of Contents

Advertisement

FX
-20SSC-H Positioning Block User's Manual
3U
7.7

Ring counter setting (Ver.1.10 or later)

This function causes the current address to perform the ring operation within the range from 0 to the preset
ring counter upper limit value.
The current address (user) performs the ring operation within the range from 0 to the preset ring value.
The current address (pulse) performs the ring operation within the range from 0 to the preset ring value
converted into pulses.
1. How to make the current address perform the ring operation
Specify the following settings.
Setting item
Ring counter setting
Ring counter upper limit value
2. Applicable positioning operations
• Operations allowing the ring operation
- Mechanical zero return
- JOG operation
- 1-speed positioning operation
- Interrupt 1-speed constant quantity feed
- 2-speed positioning operation
- Interrupt 2-speed constant quantity feed
- Interrupt stop
- Variable speed operation
- Multi-speed operation
- Manual pulse generator operation
- Reciprocal movement instruction
(Ver.1.10 or later)
54
→ For the related parameters, control data and monitor data, refer to Section 7.11
ON
Set the ring value for the current address.
1 to 2,147,483,646 [User unit]
7 Before Starting Positioning Operation
7.7 Ring counter setting (Ver.1.10 or later)
Description
• Operations not allowing the ring operation
- Linear interpolation
- Linear interpolation (interrupt stop)
- Circular interpolation