-20SSC-H Positioning Block User's Manual
3U
6.3.2

FX Configurator-FP and 20SSC-H

The data transfer between FX Configurator-FP and 20SSC-H via the PLC is as follows.
1. From 20SSC-H (buffer memory) to FX Configurator-FP [A in the figure above]
The following data is read from the buffer memory in 20SSC-H to FX Configurator-FP.
• Positioning parameters
• Servo parameters
• Table information
• Monitor data (operation status, action status, input signal status, etc.)
2. From FX Configurator-FP to 20SSC-H (buffer memory) [B in the figure above]
The following data is written from FX Configurator-FP to the buffer memory in 20SSC-H.
• Positioning parameters
• Servo parameters
• Table information
• Control data (new current values, speed change, operation test command, etc.)
3. From FX Configurator-FP (buffer memory in 20SSC-H) to 20SSC-H (flash memory)
[C in the figure above]
The following data is saved from the buffer memory in 20SSC-H to the flash memory according to the save
command sent from FX Configurator-FP.
• Positioning parameters
• Servo parameters
• Table information
FX Configurator-FP Setting/monitoring tool
(A)
(B)
Sequence
program
FX
/FX
c PLC
3U
3U
6 Memory Configuration and Data Operation
F X
-20SSC-H
3 U
Buffer memory (BFM)
- Positioning parameters
- Servo parameters
- Table information
- Monitor data
- Control data
(C)
Flash memory (ROM)
- Positioning parameters
- Servo parameters
- Table information
6.3 Data Transfer Process