Mitsubishi FX3U-20SSC-H User Manual page 175

Hide thumbs Also See for FX3U-20SSC-H:
Table of Contents

Advertisement

FX
-20SSC-H Positioning Block User's Manual
3U
From previous page
Select X-axis operation command.
X-axis error reset
X000
X-axis STOP
X001
X-axis forward rotation limit
X002
X-axis reverse rotation limit
X003
X-axis forward rotation JOG
X004
X-axis reverse rotation JOG
X005
X-axis mechanical zero return
X006
RUN monitor
M8000
RUN monitor
M8000
X-axis start command
X007
X-axis positioning at 1-step speed
M0
X-axis table operation (individual)
M9
M10
X-axis table operation (simultaneous)
To next page
From previous page
M20
M21
M22
M23
M24
M25
M26
M27
M28
M29
FNC 12
D500
U0\G500
DMOV
FNC 12
D502
U0\G502
DMOV
FNC 12
D521
U0\G521
MOV
To next page
12 Program Example
12.4 Sequence Program
X-axis error reset
X-axis STOP
X-axis forward
rotation limit
X-axis reverse
rotation limit
X-axis forward
rotation JOG
X-axis reverse
rotation JOG
X-axis mechanical
zero return command
Always OFF
X-axis relative/absolute
address specification
X-axis START
command
Target address 1 for X-axis
1-speed positioning
D501,D500
BFM #501,#500
Operation speed 1 for X-axis
1-speed positioning
D503,D502
BFM #503,#502
Table operation start No. for X-axis
(XY-axis) D521
BFM #521