Mitsubishi FX3U-20SSC-H User Manual page 194

Hide thumbs Also See for FX3U-20SSC-H:
Table of Contents

Advertisement

FX
-20SSC-H Positioning Block User's Manual
3U
BFM number
X axis
Y axis
Control command
BFM #522
enable/disable
BFM #523
Control command
Manual pulse input
BFM
BFM
magnification
#525,#524
#625,#624
(numerator)
Manual pulse input
BFM
BFM
magnification
#527,#526
#627,#626
(denominator)
MPG response
BFM #528
BFM #628
(Ver. 1.10 or later)
MPG input selection
BFM #529
(Ver. 1.10 or later)
Ring operation rotation
direction for absolute
BFM #530
BFM #630
address
(Ver. 1.10 or later)
*1.
For details on the user units, refer to the section given below.
*2.
-2,147,483,648 to 2,147,483,647 with Variable Speed operation.
*3.
BFM #619 (b1) is not available.
188
Item
Model code: control command enabled
Other than model code: control command disabled
b0
Stores positioning parameters of X axis (BFM#14000 to
BFM #14199) to flash memory
b1
Stores positioning parameters of Y axis(BFM#14200 to
BFM #14399) to flash memory
b2
Stores table information of X axis (BFM #1000 to
BFM #3999) to flash memory
b3
Stores table information of Y axis (BFM #4000 to
BFM #6999) to flash memory
b4
Stores table information of XY axes (BFM #7000 to
BFM #12999) to flash memory
b5
Stores servo parameters of X axis (BFM #15000 to
BFM #15199) to flash memory
b6
Stores servo parameters of Y axis (BFM #15200 to
BFM #15399) to flash memory
b7
Not available
b8
Initializes positioning parameters of X axis (BFM #14000 to
BFM #14199)
b9
Initializes positioning parameters of Y axis (BFM #14200 to
BFM #14399)
b10 Initializes table information of X axis (BFM #1000 to
BFM #3999)
b11 Initializes table information of Y axis (BFM #4000 to
BFM #6999)
b12 Initializes table information of XY axes (BFM #7000 to
BFM #12999)
b13 Initializes servo parameters of X axis (BFM #15000 to
BFM #15199)
b14 Initializes servo parameters of Y axis (BFM #15200 to
BFM #15399)
b15 Not available
1 to 1,000,000 times
1 to 1,000,000 times
1 to 32767
0: X input - X opr / Y input - Y opr
1: X input - Y opr
2: X input - X and Y opr
0: Direction for shorter rotation
1: Direction where the current value increases (clockwise)
2: Direction where the current value decreases
(counterclockwise)
Appendix A: LIST OF PARAMETERS AND DATA
Description/Setting range
Appendix A-2 Control Data Table
Default
Reference
value
K0
subsection 11.4.14
H0000
subsection 11.4.15
K1
subsection 11.4.16
K1
subsection 11.4.17
K4
Subsection 11.4.18
K0
Subsection 11.4.19
K0
Subsection 11.4.20
→ Refer to Section 7.9