8.2.3

Related parameters, control data and monitor data

Item
Positioning parameters
Operation
parameter 2
Maximum speed
JOG speed
JOG determination time
Acceleration time
Deceleration time
Positioning parameters
External signal
selection
Current address ring value
(Ver.1.10 or later)
Control data
Override setting
Operation
command 1
Monitor data
Current address (user)
Current address (pulse)
Received target speed
(Ver.1.20 or later)
*1.
For user units, refer to the following.
80
X-axis
Ring counter setting
BFM #14002 b3
(Ver.1.10 or later)
BFM #14009,#14008
BFM #14013,#14012
BFM #14014
BFM #14018
BFM #14020
FLS/RLS signal
BFM #14044 b0
selection
FLS/RLS signal
BFM #14044 b8
logic
BFM #14101, #14100 BFM #14301, #14300 Setting range : 1 to 2,147,483,646 (user unit)
BFM #508
Forward rotation
BFM #518 b2
limit (LSF)
Reverse rotation
BFM #518 b3
limit (LSR)
Forward rotation
BFM #518 b4
JOG
Reverse rotation
BFM #518 b5
JOG
Simultaneous start
BFM #518 b10
command
In-process speed
BFM #518 b12
change prohibition
BFM #1,#0
BFM #3,#2
BFM #27,#26
BFM number
Y-axis
BFM #14202 b3
BFM #14209,#14208
BFM #14213,#14212
BFM #14214
BFM #14218
BFM #14220
BFM #14244 b0
BFM #14244 b8
BFM #608
BFM #618 b2
BFM #618 b3
BFM #618 b4
BFM #618 b5
BFM #618 b10
BFM #618 b12
BFM #101,#100
BFM #103,#102
BFM #127,#126
8 Manual Control
8.2 JOG Operation
Description
OFF: Disables the ring operation.
ON : Enables the ring operation.
Setting range: 1 to 2,147,483,647(user unit)
Setting range: 1 to 2,147,483,647(user unit)
Setting range: 0 to 5000ms
Setting range: 1 to 5000ms
Setting range: 1 to 5000ms
OFF: The FLS/RLS signal of the servo amplifier
is not used.
ON: The FLS/RLS signal of the servo amplifier
is used.
OFF: The NO contact for the FLS/RLS signal
logic of the servo amplifier.
ON: The NC contact for the FLS/RLS signal
logic of the servo amplifier.
Specify the ratio (percent) of the actual
operation speed to the operation speed. Setting
×
range: 1 to 30000(
0.1%)
The 20SSC-H decelerates to stop at this
parameter ON during forward rotation output
The 20SSC-H decelerates to stop at this
parameter ON during reverse rotation output
Forward pulses are output while this parameter
remains ON.
Reverse pulses are output while this parameter
remains ON.
The 20SSC-H simultaneously starts the X and
Y-axes operation at the X-axis start command
ON.
OFF: The speed and target position change
commands
during
positioning
operation are valid.
ON: The speed and target position change
commands
during
positioning
operation are invalid.
Setting range:-2,147,483,648 to
2,147,483,647(user units)
Setting range:-2,147,483,648 to
2,147,483,647PLS
-2,147,483,648 to 2,147,483,647(user unit)
→ Refer to Section 7.9
*1
*1
*1
control