14
. BATTERY/CHARGING SYSTEM/
A.C. GENERATOR
Disconnect the A.C. generator pink and yellow
wires and measure the resistance between the
pink and yellow wires.
Resistance: 0.2Ω(at 20 )
Replace the A.C. generator charging coil if the
reading is not within the specifications.
14-7