Service Setting: a b
1
*********************
Service Status
2
Network Status
3
Test Page
Altitude Adj.:
1 *Normal
*********************
2
High 1
3
High 2

MC (Main charger output setting)

This sets the output of the main charger. When print quality has deteriorated, the output of the main charger
can be changed to restore print quality.
NOTE:
This menu only appears when the Altitude Adj. (Altitude adjustment setting) on page 8-137 is set to
[Normal].
Use the procedure below to set the main charger output setting.
Sys. Menu/Count.:a b
;
Document Box
<
Edit Destination
=
*********************
Adjust/Maint.
Adjust/Maint.:
1
*********************
Copy Denst. Adj.
2
Send/Box Density
3
Backgrnd Density
4
[ Exit
]
5
6
a b
7
8
1
[ Exit
]
2
a b
[ Exit
]
3
8-138
Default Setting (System Menu)
Press the OK key. The Service Setting menu
appears.
Press the  or  key to select [Altitude Adj.].
Press the OK key. Altitude Adj. appears.
Press the  or  key to select [Normal], [High 1]
or [High 2].
Press the OK key. Completed. is displayed and the
screen returns to the Service Setting menu.
In the Sys. Menu/Count. menu, press the  or 
key to select [Adjust/Maint.].
Press the OK key. The Adjust/Maint. menu
appears.
Press the  or  key to select [Service Setting].