Information required:
1. Select desired language (ENGLISH, FRANÇAIS, ESPAÑOL).
2. Select country / region.
3. Select time and date which includes time, date, time zone and daylight
savings time (ON/OFF).
4. Temperature unit (Fahrenheit or Celsius).
Once completed touch continue.

Equipment Found Screen

This screen will display any communicating equipment the system has
detected (air handler, furnace, outdoor unit, Smart Hub and zoning control)
during initial powering up of the system.
NOTE - When a Lennox Equipment Interface Module (EIM) is used and
configured either as a furnace or air handler, then the component would appear
as either EIM-Furnace or EIM-Air Handler. When using a EIM the outdoor unit
may be either a Lennox communicating or any standard 24VAC
non-communicating unit.
NOTE - Not all equipment may be visible from the equipment found system
screen. Use a finger to swipe up to access additional information (if applicable)
listed at the bottom of the system box.
If non-communicating equipment needs to be added, it can be done so from
this screen.

Non-Communicating Equipment

When selecting the non-communicating (24VAC) equipment icon a screen will
appear listing various equipment that can be added. When selecting a
applicable component, a green check will appear next to the item. The capacity
selection of the outdoor unit will also be displayed on the screen after selecting
the applicable outdoor equipment type.
NOTE - Also a temporary dialog box will appear indicating: Updating - Wait
while we check for dependencies.
NOTE - Selecting an outdoor unit type only appears if a communicating outdoor
unit is not detected by the system. Selections are one or two stage heat pumps
or air conditioners. Outdoor unit capacity will also have to be set. Other
equipment that can be added are humidifiers and dehumidifiers.
Once completed touch done which will display the equipment found screen.
There the additional non-communicating equipment will now be displayed
along with the communicating equipment.
Once completed touch continue.

Reminders

This screen allows you to set reminders as either disabled or 3, 6, 12 or 24
months and also custom by specific date. The other options on this screen is
to trigger the reminder event either by calendar or actual system run-time.
Reminders may be set for replace filter 1, replace filter 2, replace UV blub,
replace humidifier pad, PureAir™ maintenance and maintenance reminder.
Once a reminder is set for a specific item, touch done to return to the previous
screen. An "expires on date" will appear next to the item just set.
Once completed touch continue.

IHarmony Zoning

This screen will only appear if the iHarmony
This screen allows you to rename each zone using provided preset names or
custom name. This screen will not appear if iHarmony
is not detected by the system.
Touch on any zone to rename it. A screen will display that list several predefined
names that can be used which are master bedroom, guest bedroom, kitchen,
living room, media room, dining room, library or custom. When a predefine
name is selected, a green check-mark will appear next to the selected name.
When creating a custom name, touch custom, enter a name and touch back to
return to the previous screen. A new unique zone name can be created for all
four zones.
Once done, touch done to return to the zoning screen and verify the new name
is being used for the specific zone.
Once completed touch continue.
SET UP AIRFLOW PER ZONE
This screen will allow the installer to setup the airflow per zone. The types of
circulation per zone are:
S
Blower Circulation Airflow (gray) which includes total, assigned,
minimum and maximum airflow
S
Heating Circulation Airflow (red) which includes total, assigned,
minimum and maximum airflow
S
Cooling Circulation Airflow (blue) which includes total, assigned,
minimum and maximum airflow.
Touch on the circled green arrow to touch a specific zone. The that zone
settings will expand to allow the installer to adjust CFMs for each circulation
airflow type. Use the plus and minus buttons to adjust CFMs up and down.
Once completed touch continue. The next screen that will appear is the Dealer
Control Center.