Lennox iComfort S30 Installation And Setup Manual page 50

Hide thumbs Also See for iComfort S30:
Table of Contents

Advertisement

Table 1 Alert Codes and Troubleshooting
Applicable
Alert
Priority
System
Code
Condition
Component(s)
111
Critical
Furnace
112
Critical
Furnace
113
Critical
Furnace
Furnace, air
Moderate /
handler, equipment
114
Critical
interface or
IHarmony
Furnace, air han­
dler, equipment in­
115
Critical
terface module and
IHarmony
Furnace or Air
116
Critical
Handler
117
Minor
Furnace
Critical alerts are displayed on the Home screen, in the Homeowner alert button, and in the Installer alert button.
Minor and moderate alerts are found only in the Installer alert button.
Actual Displayed Alert
Component or System Operational State and Troubleshooting Tip
Text
The unit is reporting that its power and neutral lines are reversed.
Turn off the power to the system and correct the line power voltage wiring.
Line Polarity Reversed
System resumes normal operation five seconds after critical condition is re­
covered.
The reporting component cannot find earth ground. The thermostat will shut
down the system.
Provide proper earth ground to the equipment.
No Ground Connection
System resumes normal operation five seconds after critical condition is re­
covered.
Line voltage high (voltage higher than nameplate rating).
Provide power voltage within proper range.
High AC Line Voltage
System resumes normal operation five seconds after critical condition is re­
covered.
There is a frequency / distortion problem with the power to a specific system
component. There is a frequency / distortion problem with the power to a
specific system component.
This alert code may indicate transformer overloading.
Check the voltage and line power frequency.
Check the generator operating frequency, if the system is running on back-
up power.
AC Line Frequency
Correct voltage and frequency problems.
/Distortion Prob
System will resume normal operation five seconds after fault recovered.
All applicable system component outputs are disabled – moderate condi­
tion.
After 10 minutes, the priority condition is escalated – critical condition.
Damper control module will operate in central mode only until proper volt­
age is restored or frequency distortion is resolved – moderate condition.
24VAC power to a system component control is lower than the required
range of 18 to 30VAC.
Check and correct voltage.
Check for additional power-robbing system components (devices) con­
Low Secondary (24VAC)
nected to system.
Voltage
This alert code may require the installation of an additional or larger VA
transformer.
Damper control module will operate in non-zone mode until proper voltage
is restored.
IComfort
High Secondary (24VAC)
is high (18 to 30 VAC).
voltage
Will display Furnace or Air Handler High Secondary (24VAC) voltage.
The reporting unit has poor earth grounding.
Provide proper grounding for the system component (device).
Poor Ground
Check for proper earth ground to the system.
®
S30 Control system will display this code when 24VAC power
50
How to clear alert code
Automatically clears when the
system detects the issue no
longer exists.
Automatically clears when the
system detects the issue no
longer exists.
Automatically clears when the
system detects the issue no
longer exists.
Automatically clears when the
system detects the issue no
longer exists.
Automatically clears when the
system detects the issue no
longer exists.
Check and correct voltage. Check
for proper line voltage (120V,
240V, etc.) to equipment. Clears
when control senses proper volt­
age.
Automatically clears 30 seconds
after the issue is corrected.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents