Lennox iComfort S30 Installation And Setup Manual page 11

Hide thumbs Also See for iComfort S30:
Table of Contents

Advertisement

SMART HUB
MAG-
MOUNT
26L56 CURRENT SENSING RELAY KIT.
NOTE: PASS THE BLOWER MOTOR L1 WIRE
THROUGH THE
CURRENT LOOP ON THE CURRENT SENSING
RELAY AS SHOWN.
HVAC HEAT OR COOL CALL, OR THE FAN IS IN CONTINUOUS OPERATION, THE VENTILATION CONTROLLER WILL
OPEN OA DAMPER TO VENTILATE IF THE OUTDOOR TEMPERATURE AND INDOOR HUMIDITY ARE WITHIN THE
LIMITS OF THE VENTILATION CONTROLLER.
LVCS. SET CYCLE TIME TO 1 HOUR; SET VENTILATION TIME TO 60 MINUTES.
®
NOTE: USE THE ICOMFORT
S30 CIRCULATE FAN PERCENTAGE OF ON TIME TO CONTROL VENTILATION TIME.
LVCS VENTILATION CONTROL
SYSTEM
SLP98 & G71MPP FURNACE
(IFC) OR AIR HANDLER (AHC)
Figure 10. Optional Accessories Wiring
ICOMFORT
FURNACE
ICOMFORT
OR AIR
OUTDOOR AIR
f
HANDLER
CONDITIONING
OR HEAT PUMP
(POWER COMPANY INTERRUPTION
SYSTEMS ARE WIRED SAME AS
OVERFLOW SWITCH)
ICOMFORT
FURNACE OR AIR
HANDLER
HEPA BYPASS FILTER X2680 HEPA
ICOMFORT
FURNACE OR AIR
HANDLER
11
ICOMFORT 2-STAGE
FURNACE
DS
CUT
R-DS
W914
R
STANDARD 1 OR 2 STAGE
AC OR HP UNIT
INTERLOCK KIT
PASS INDOOR BLOWER MO­
TOR COMMON WIRE
THROUGH CURRENT LOOP.
SEE HEPA INTERLOCK KIT
FOR INSTALLATION DETAILS