Table 1 Alert Codes and Troubleshooting
Applicable
Alert
Priority
System
Code
Condition
Component(s)
346
Critical
Air handler
Furnace, air
handler or
347
Critical
equipment
interface module
Furnace or air
348
Critical
handler
349
Critical
Furnace
350
Critical
Air handler
351
Critical
Air handler
352
Critical
Air handler
353
Critical
Air handler
354
Critical
Air handler
Critical alerts are displayed on the Home screen, in the Homeowner alert button, and in the Installer alert button.
Minor and moderate alerts are found only in the Installer alert button.
Actual Displayed Alert
Component or System Operational State and Troubleshooting Tip
Text
The heat pump configuration link is not cut on the air handler control.
√
Configuration link not cut on air handler control.
HP Jumper Not Removed
√
Cut O to R.
√
This is only applicable with non-communicating heat pump with communi
cating indoor unit.
The Y1 relay on the applicable system component has failed. Either the pilot
relay contacts did not close or the relay coil did not energize.
√
System operation will stop.
Relay Y1 Failure
√
Possible Y1 relay / stage 1 failure.
√
Pilot relay contacts did not close or the relay coil did not energize;
√
There is no input back to the applicable system component control.
The Y2 relay on the applicable system component has failed. Either the pilot
relay contacts did not close or the relay coil did not energize.
√
Possible Y2 relay / stage 2 failure.
Relay Y2 Failure
√
Furnace pilot relay contacts did not close or the relay coil did not energize
√
No input back to furnace or air handler control.
The O to R link on the furnace needs to be restored.
√
Configuration link R to O needs to be restored.
IFC Error Check Jumper
O to R
√
Repair cut link by hard-wiring the R to O terminals on the terminal strip.
√
Only applicable in non-communicating mode.
The air handler's electric heat is not configured or incorrectly configured.
√
Heat call with no configured or incorrectly configured electric heat.
Electric Heat Not
√
Check for proper configuring under Configuring Electric Heat Stages in the
Configured
air handler installation instructions. Smart Hub MUST be removed from the
system before configuring electric heat.
There is an issue with the air handler's first stage electric heat.
√
Either the pilot relay contacts did not close or the relay coil in the electric
Electric Heat Stage 1
heat section did not energize.
Problem
√
Possible heat section / stage 1 failure.
√
Air handler will operate on HP first stage for reminder of the heat call.
There is a issue with the air handler's second stage electric heat.
√
Either the pilot relay contacts did not close or the relay coil in the electric
Electric Heat Stage 2
heat section did not energize.
Problem
√
The air-handler will operate on first stage electric heat until the issue is re
solved.
There is a issue with the air handler's third stage electric heat.
√
Either the pilot relay contacts did not close or the relay coil in the electric
Electric Heat Stage 3
heat section did not energize.
Problem
√
The air-handler will operate on first stage electric heat until the issue is re
solved.
There is a issue with the air handler's fourth stage electric heat.
√
Either the pilot relay contacts did not close or the relay coil in the electric
Electric Heat Stage 4
heat section did not energize.
Problem
√
The air-handler will operate on first stage electric heat until the issue is re
solved.
57
How to clear alert code
Automatically clears when the
system detects that the issue no
longer exists.
Automatically clears after reset
and Y1 input sensed.
Automatically clears when the
system detects that the issue no
longer exists.
Automatically clears when the
system detects that the issue no
longer exists.
Automatically clears after electri
cal heat detection is successful.
Automatically clears after fault re
covered.
Automatically clears after fault re
covered.
Automatically clears after fault re
covered.
Automatically clears after fault re
covered.