ADJUSTING SYSTEM DEVICES SETTINGS
1. Press any component listed under system devices to change specific communicating equipment parameters and edit details of devices in the system.
2. Use the arrows to highlight a setting and then press edit (figure 9A). In the example, the low heating airflow is changed from the default (400) to 325 (figure 9B).
After changing, press save. (note the current value has changed; figure 9C). Some changes may affect other settings and, if so, those affected will appear in red
and require changing/saving to clear the red settings.
3. When finished, press back; equipment parameters screen then press next. "Select tests to run screen appears"; either run tests as before or press skip tests.
System
Equipment Name
Heating Airflow Control Type
Low Heating Airflow
High Heating Airflow
High Cooling Airflow
Airflow Profile - Cooling
System
High HP Airflow
Equipment Name
Continuous Indoor Blower Airflow
Heating Airflow Control Type
Heating Indoor Blower OFF Delay
Low Heating Airflow
High Heating Airflow
9:39 am Aug 15, 2012
High Cooling Airflow
Airflow Profile - Cooling
Default is 400, inc: 25
High HP Airflow
Continuous Indoor Blower Airflow
Heating Indoor Blower OFF Delay
9:39 am Aug 15, 2012
Figure 9. Edit Equipment Details
The following tables list the system devices settings available from the installer setup screens.
System
Heat Pump
Furnace
Thermostat
9:39 am Aug 15, 2012
Parameter Name:
Equipment Name
Filter 1 Timer Selection
Filter 2 Timer Selection
UV Bulb Timer Selection
Humidifier Pad Timer Selection
PureAirt Timer Selection
Smooth Setback Recovery
Electric Heat Control Mode
EvenHeat Discharge Temp
Gas Heat Control Mode
Number of Gas Heating Stages (SLP98V only) (staged selection)
Modulating Gas Heating Steady State PI (SLP98V only)
Modulating Gas Heat Step Change PI (SLP98V only)
Modulating HP Heating Cycles Per Hour (XP25 only)
Modulating HP Electric Heating Switching Point (XP25 only)
Modulating HP Heating Steady State PI Gain (XP25 only)
Modulating HP Heating Step Change PI Gain (XP25 only)
Modulating Cooling Steady State PI Gain (XC25 and XP25 only)
Modulating Cooling Step Change PI Gain (XC25 and XP25 only)
Modulating Cooling Cycles Per Hour (XC25 and XP25 only)
Auto Changeover - Temp Dead-band
Max Heat Set point
Min Cool Set point
Heat Cool Stages Lock In
507152-01
Low Heating Airflow
current value:
400
edit
reset All
Low Heating Airflow
current value:
back
325
Low Heating Airflow
Range is 325 to 450
set-to
325
back
cancel
save
Table 2. System Devices > System
system devices
edit
Reset All
To adjust a setting,
highlight it, then
press Edit
System
back
Default
Calendar Time
Calendar Time
Calendar Time
Calendar Time
Calendar Time
Enabled
Standard
85ºF
Staged
4
Standard
Standard
4.0
1.0
Standard
Standard
Less
Aggressive
Less
Aggressive
4.0
5ºF
90ºF
60ºF
60ºF
Page 6
about
resetAll
edit
next
Parameter Value Setting
(keyboard input screen)
Calendar Time, Run Time
Calendar Time, Run Time
Calendar Time, Run Time
Calendar Time, Run Time
Calendar Time, Run Time
Enabled, Disabled
Standard, Evenheat
85ºF to 130ºF
Staged, Variable Capacity, Load Tracking
Variable Capacity
1, 2, 3 or 4
Less Aggressive, More Aggressive, Standard
Less Aggressive, More Aggressive, Standard
3.0 to 6.0
0.0 to 2.0
Less Aggressive, More Aggressive, Standard
Less Aggressive, More Aggressive, Standard
Less Aggressive, More Aggressive, Standard
Less Aggressive, More Aggressive, Standard
3.0 to 6.0
3 to 9ºF
40 to 90ºF
60 to 99ºF
60 to 99ºF
Increment
15ºF
0.5
0.25
0.5
1ºF
1ºF
1ºF
1ºF
7/2013