Sign In
Upload
Manuals
Brands
Weinmann Manuals
Medical Equipment
MEDUVENT Standard
Weinmann MEDUVENT Standard Ventilator Manuals
Manuals and User Guides for Weinmann MEDUVENT Standard Ventilator. We have
5
Weinmann MEDUVENT Standard Ventilator manuals available for free PDF download: Instructions For Use Manual, Manual, Step-By-Step Instructions
Weinmann MEDUVENT Standard Instructions For Use Manual (236 pages)
Ventilator
Brand:
Weinmann
| Category:
Medical Equipment
| Size: 17 MB
Table of Contents
Table of Contents
2
Introduction
8
About this Document
8
Explanation of Warnings
8
Safety
9
Intended Purpose
9
Indications and Medical Purpose
9
Patient Target Group(S)
10
Intended Users
10
Contra-Indications
10
Intended Environments of Use
10
Undesirable Side Effects and Complications
11
Clinical Benefit of the Product
12
Exclusions and Limitations of the Intended Purpose
12
Requirements on the User
13
Requirements on the Operator
13
Safety Information
13
Description
24
Overview
24
Control Panel and Connections
26
Display
28
Ventilation Mode with Bar Graph View (Example)
28
Ventilation Mode with Curve View (Example)
30
Measured Values View (Example)
31
Parameter View (Example)
32
Ventilation Mode with Extended Curve View (Example)
33
Night Colors
34
Symbols in the Display
35
Accessories and Other Parts
37
Power Supply
37
Breathing Circuit
38
Miscellaneous
40
Reusable Breathing Circuit
42
Disposable Breathing Circuit
44
Rechargeable Battery and Battery Status Indicator
46
Transport Options
47
Labels
48
Preparation
51
Mounting the Device
51
Connecting a Power Supply
51
Connecting the Breathing Circuit
53
Connecting the Reusable Breathing Circuit
53
Connecting the Disposable Breathing Circuit
56
Flowline-Flowcheck Connection Line (Optional) to the Accessories Connection
56
If Present: Connect Medutrigger or Medutrigger with
56
In the Case of Invasive Ventilation: Connect the Patient Valve of the Breathing Circuit to the Tracheal Tube Following Intubation
57
Connecting the Flowcheck Sensor
58
Connecting the Oxygen Supply
60
Using the SD Card
62
Inserting the SD Card
62
Removing the SD Card
63
Converting the Device
64
Converting the Device to a Disposable Breathing Circuit
64
Converting the Device to a Reusable Breathing Circuit
65
Function Check
66
Intervals
66
Preparing for the Function Check
66
Performing the Function Check
67
Checking the Reusable Patient Valve
75
Operation
76
Intended Operating Position
77
Switching on the Device
78
Navigating in the Device
79
Starting Ventilation
80
Starting Ventilation for a Patient Group
82
Starting Ventilation for a New Patient
83
Changing Ventilation Mode
85
Changing Ventilation Parameters
87
Changing Patient Group
89
Changing Alarm Limits
90
Changing the Alarm Limit of a Measured Value Directly
91
Accessing the Alarm Limits with the Alarm Mute Button
93
Activating Apnea Ventilation
94
Presetting the Ventilation Mode for Apnea Ventilation in the Operator Menu
94
Activating or Deactivating Apnea Ventilation During Ventilation
95
Setting the Alarm Limit for the Apnea Alarm
96
Ending Apnea Ventilation
97
Supplying Oxygen
98
Setting Oxygen Concentration
98
Calculating Operating Time
100
Switching off the Device
101
Disconnecting the Oxygen Supply
101
After Use
101
Hygienic Reprocessing
102
Hygienic Reprocessing Intervals
106
Preparing for Hygienic Reprocessing
106
Disassembling the Reusable Breathing Circuit
107
Disassembling the Adapter for Disposable Breathing Circuit
109
Reprocessing Parts Mechanically
110
Reprocessing Parts Mechanically in a Washer-Disinfector
110
Mechanically Reprocessing the Protective Sleeve and Hook and Loop Strap with Clip
111
Cleaning Parts Manually
112
Cleaning Device and Accessories Manually
112
Cleaning the Reusable Measuring Circuit Manually
114
Cleaning the Reusable Breathing Circuit Manually
115
Disinfecting Parts by Wiping
117
Disinfecting Parts by Immersion
118
Disinfecting the Reusable Measuring Circuit by Immersion
118
Disinfecting the Reusable Breathing Circuit by Immersion
119
Preparing Parts for Reuse
121
Assembling the Reusable Breathing Circuit
122
Fitting the Adapter for Disposable Breathing Circuit
125
Cleaning and Disinfection Plan
125
Definition of the Levels of Disinfection
125
Device and Accessories
126
Breathing Circuits
127
User Menu
130
Navigating the User Menu
130
User Menu Structure
131
Settings in the User Menu
132
Emergency Mode
132
Alarm Limits
133
Ventilation Mode
134
Ventilation Parameters
135
Display Settings
136
Device Settings
137
Accessing Quick Settings from the Start Menu
138
Operator Menu
140
Activating Operator Menu
140
Operator Menu Structure
141
Device Settings
142
Factory Setting
142
Ventilation Presets
144
Changing the Access Code
147
Options
148
Enabling Options
148
Description of Options
150
Importing/Exporting Data
151
Export Configuration
151
Software Update
152
Performing a Software Update
152
Device Information
154
Battery Information
155
Ventilation Modes
156
Classification of Ventilation Modes
156
Trigger Options
157
Ventilation Parameters and Measured Values
158
Ventilation Parameters
158
Measured Values
159
Description of the Ventilation Modes
161
Ippv
161
Bilevel + ASB (Optional)
163
Cpap
164
CPAP + ASB (Optional)
166
Apcv (Optional)
169
PCV (Optional)
171
PRVC + ASB (Optional)
172
SIMV (Optional)
174
SIMV + ASB (Optional)
175
S-IPPV (Optional)
177
Manual
179
CPAP + PS (Optional)
181
PRVC + PS (Optional)
183
Equivalence Table
185
Alarms and Faults
186
Alarm Messages
187
High-Priority Alarms (Red)
187
Medium-Priority Alarms (Yellow)
189
Low-Priority Alarms (Turquoise)
190
Faults
190
Maintenance
192
Intervals
192
Maintenance Reminder
194
Maintaining the Reusable Breathing Circuit
195
Replacing the Hygiene Filter
195
Removing the Hygiene Filter
196
Inserting the Hygiene Filter
196
Replacing the Rechargeable Battery
197
Removing the Rechargeable Battery
197
Installing the Rechargeable Battery
200
Sending in Parts
202
Storage
203
Disposal
204
Electronic Waste
204
Rechargeable Battery
204
Plastics
204
Hygiene Filter
204
Contaminated Parts
205
Scope of Supply
206
Version Supplied (Example)
206
Accessories and Other Parts
206
Supplementary Information
207
Protective Caps
208
Technical Data
211
Device
211
Specification
211
Rechargeable Battery
218
Power Supply Unit and Charger
219
Breathing Circuits
220
Connection Lines
222
Flowcheck Sensor
222
Block Diagram
223
Electromagnetic Compatibility (EMC)
223
Guidelines and Manufacturer's Declaration - Electromagnetic Immunity
225
Compliance Level
225
Calculating Tidal Volume on the Basis of Height
229
Service Data
230
Structure and Content of Service Data
230
Recorded Function Checks (Fcheck File)
230
Recorded Session Data
231
Alarms
232
Alarm Delay Times
232
Recording of the Alarm System
232
Warranty
233
EU Declaration of Conformity
233
Advertisement
Weinmann MEDUVENT Standard Instructions For Use Manual (188 pages)
Brand:
Weinmann
| Category:
Medical Equipment
| Size: 5 MB
Table of Contents
Table of Contents
2
1 Introduction
6
About this Document
6
Explanation of Warnings
6
2 Safety
7
Intended Purpose
7
Clinical Benefit of the Product
8
Requirements on the User
9
Using the Device Safely
9
3 Description
20
Overview
20
Control Panel and Display
22
Symbols in the Display
25
Accessories and Other Parts
26
Rechargeable Battery and Battery Status Indicator
32
Transport Options
33
4 Preparation
34
Connecting a Power Supply
34
Mounting the Device
34
Connecting the Breathing Circuit
36
Connecting the Oxygen Supply
41
Converting the Device
43
5 Function Check
45
Intervals
45
Preparing for the Function Check
45
Performing the Function Check
46
Checking Reusable Breathing Circuit
53
6 Operation
54
Switching on the Device
55
Navigating in the Device
56
Starting Ventilation
57
Changing Ventilation Mode
61
Changing Ventilation Parameters
63
Changing Patient Group
65
Supplying Oxygen
66
Switching off the Device
69
Disconnecting the Oxygen Supply
69
After Use
69
7 Hygienic Reprocessing
70
Hygienic Reprocessing Intervals
73
Disassembling/Assembling the Reusable Breathing Circuit
74
Preparing for Hygienic Reprocessing
74
Cleaning Parts Manually
79
Disinfecting Parts by Wiping
83
Disinfecting Parts by Immersion
84
Disinfecting the Reusable Measuring Circuit by Immersion
86
Reprocessing Parts Mechanically
88
Steam-Sterilizing Parts (Optional)
90
Preparing Parts for Reuse
91
Cleaning and Disinfection Plan
92
8 User Menu
98
Navigating the User Menu
98
User Menu Structure
99
Settings in the User Menu
100
9 Operator Menu
105
Activating the Operator Menu
105
Operator Menu Structure
106
Device Settings
107
Patient Presets
109
Changing the Access Code
111
Options
112
Importing/Exporting Data
114
Software Update
117
Device Information
119
Battery Information
120
10 Description of the Modes
121
Ippv
121
Cpap
122
CPAP + PS (Optional)
123
PRVC + PS (Optional)
125
SIMV (Optional)
126
S-IPPV (Optional)
127
Manual
129
11 Alarms and Faults
131
Alarm Messages
132
Faults
135
12 Maintenance
137
Intervals
137
Maintenance Reminder
139
Maintaining the Reusable Breathing Circuit
140
Replacing the Hygiene Filter
140
Replacing the Rechargeable Battery
142
Sending in Parts
147
13 Storage
148
14 Disposal
149
Electronic Waste
149
Hygiene Filter
149
Plastics
149
Rechargeable Battery
149
Contaminated Parts
150
15 Scope of Supply
151
Standard Scope of Supply
151
Accessories and Other Parts
152
16 Technical Data
157
Device
157
Rechargeable Battery
163
Power Supply Unit and Charger
164
Breathing Circuits
165
Block Diagram
167
Electromagnetic Compatibility (EMC)
167
Calculating Tidal Volume on the Basis of Height
173
Exported Service Data
174
Alarm Delay Times
176
17 Symbols and Labels
177
Labels on the Device
177
Labels on the Accessories
181
Labels on the Packaging
183
18 Warranty
184
19 EC Declaration of Conformity on Medical Devices
184
Weinmann MEDUVENT Standard Instructions For Use Manual (164 pages)
Ventilator
Brand:
Weinmann
| Category:
Medical Equipment
| Size: 12 MB
Table of Contents
Table of Contents
2
1 Introduction
6
Intended Purpose
6
Owner/Operator and User Qualification
8
2 Safety
9
Safety Information in These Instructions for Use
9
Using the Device Safely
9
3 Description
20
Overview
20
Control Panel and Display
21
Symbols in the Display
24
Accessories
25
Rechargeable Battery and Battery Status Indicator
31
Transport Options
32
4 Preparation
33
Assembling the Device
33
Connecting a Power Supply
34
Connecting the Breathing Circuit
35
Connecting the Oxygen Supply
40
Converting the Device
42
5 Function Check
44
Intervals
44
Performing the Function Check
45
Preparing for the Function Check
45
Checking the Reusable Breathing Circuit
52
6 Operation
53
Switching on the Device
54
Navigating in the Device
55
Starting Ventilation
56
Switching Ventilation Mode
60
Changing Ventilation Parameters
61
Switching Patient Group
62
Introducing Oxygen
63
Switching the Device off
65
Disconnecting the Oxygen Supply
66
After Use
66
7 Operator Menu
67
Activating the Operator Menu
67
Menu Structure
68
Device Settings
69
Patient Presets
71
Changing the Access Code
73
Options
74
Importing/Exporting Data
76
Updating Software
79
Device Information
81
Battery Information
82
8 Hygienic Reprocessing
83
Intervals
86
Preparing for Hygienic Reprocessing
87
Removing/Installing the Reusable Breathing Circuit
87
Cleaning Parts Manually
92
Disinfecting Parts by Wiping
96
Disinfecting Parts by Immersion
98
Disinfecting the Reusable Measuring Circuit by Immersion
100
Reprocessing Parts Mechanically
101
Steam-Sterilizing Parts (Optional)
103
Preparing Parts for Reuse
104
Cleaning and Disinfection Plan
105
9 Description of the Modes
109
Cpap
109
Ippv
110
Simv
111
S-Ippv
112
Manual
114
10 Alarms and Faults
116
Alarm Messages
117
Faults
120
11 Maintenance
122
Intervals
122
Maintaining the Breathing Circuit (Reusable)
123
Replacing the Hygiene Filter
124
Replacing Rechargeable Battery
126
Sending in the Device
130
12 Storage
131
Breathing Circuit/Oxygen Inlet Tube
132
13 Disposal
132
Electronic Waste
132
Hygiene Filter
132
14 Scope of Supply and Accessories
133
Rechargeable Battery
132
Accessories and Other Parts
133
Standard Product
133
Spare Parts
137
15 Technical Data
138
Technical Data, Device
138
Technical Data, Rechargeable Battery
143
Technical Data, Breathing Circuits
144
Technical Data, Power Supply Unit and Charger
144
Block Diagram
145
Technical Data on Electromagnetic Compatibility (EMC)
146
Calculating Tidal Volume on the Basis of Height
152
Exported Log Files
153
Alarm Delay Times
155
16 Symbols and Labels
156
Labels on the Device
156
Labels on the Accessories
158
Labels on the Packaging
161
17 Warranty
162
18 EC Declaration of Conformity on Medical Devices
162
Advertisement
Weinmann MEDUVENT Standard Manual (119 pages)
Brand:
Weinmann
| Category:
Medical Equipment
| Size: 16 MB
Table of Contents
Table of Contents
4
Product Description
18
Preparation and Operation
35
Description of the Modes
70
Hygienic Reprocessing
77
Function Check
88
Alarms and Faults
100
Weinmann MEDUVENT Standard Step-By-Step Instructions (28 pages)
Brand:
Weinmann
| Category:
Medical Equipment
| Size: 4 MB
Advertisement
Related Products
Weinmann MEDUMAT Transport
Weinmann MEDUCORE Standard2
Weinmann MEDUMAT Easy CPR
Weinmann Module System
Weinmann MEDUMAT EasyCPR
Weinmann MEDUMAT Basic
Weinmann MEDUMAT Basic p
Weinmann MEDUMAT Standard a
Weinmann MEDUMAT Standard
Weinmann MEDUMAT Easy
Weinmann Categories
Medical Equipment
Fan
Water Pump
Humidifier
Respiratory Product
More Weinmann Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk