Sign In
Upload
Manuals
Brands
Festo Manuals
Terminal Block
IIFB-02- Series
Festo IIFB-02- Series Valve Terminal Manuals
Manuals and User Guides for Festo IIFB-02- Series Valve Terminal. We have
2
Festo IIFB-02- Series Valve Terminal manuals available for free PDF download: Manual
Festo IIFB-02- Series Manual (133 pages)
Valve terminal/valve sensor terminal with field bus connection
Brand:
Festo
| Category:
Terminal Block
| Size: 6 MB
Table of Contents
3. Technical Description
19
Technical Description
18
Table of Contents
19
Structure
20
Valve Sensor Terminal
21
Function
25
Technical Specifications
27
Electronic Components
28
Field Bus
30
Pneumatic Components
31
Valve Sensor Terminal
36
Connection Block
38
4.2 Installing the Pneumatic Components
41
Installing the Pneumatic Components
42
Laying the Hoses
42
Preparing the Connection Block
43
Connecting the Connection Block
44
Connecting the Valves
45
Solenoid Valve (5/2-Way)
46
Solenoid Pulse Valve (5/2-Way) and Solenoid MID-Position Valve (5/3-Way)
47
Checking the Valve Functions
48
Manual Overrride
48
Designs of Manual Override
49
Testing
50
Locking the Manual Override
52
Vifb1
54
4.3 Installing the Electronic Components
55
Valve Sensor Terminal
55
Installing the Electronic Components
56
Opening and Closing the Field Bus Node
57
Configuring the Valve Terminal/Valve Sensor Terminal
58
Address Selector Switch
59
Setting the Field Bus Address
59
Dual In-Line Switch (DIL Switch)
61
Setting the Field Bus Baud Rate
62
Setting the Field Bus Protocol
62
Connecting the Valve Terminal/Valve Sensor Terminal
63
General
63
24 V Operating Voltage Connection
65
Applying the 24 V Operating Voltage
66
Field Bus Interface
69
Connecting the Field Bus Interface
70
Field Bus Cable
70
Fitting the Terminating Resistor
73
Outputs and Valve Locations
75
Additional Outputs
76
Connection Assignment of Additional Outputs
77
Inputs
78
Connection Assignment of Inputs
79
Circuitry
80
5. Commissioning
83
Commissioning
84
Configuring the PLC
84
Festo
85
Klöckner-Moeller
86
Siemens
86
Switching on the Operating Voltage
90
Addressing the Inputs and Outputs
91
Valve Locations
91
Valve Terminal
91
Valve Locations, Inputs and Additional Outputs
93
Valve Sensor Terminal
93
Status Bits
96
Festo
97
Manufacturer-Specific Features
97
Klöckner-Moeller
98
Siemens
102
6. Diagnostic and Error Treatment
108
Field Bus Node
109
LED Displays
109
Valves
111
Inputs and Additional Outputs
112
Diagnostic Byte
113
Festo
113
Klöckner-Moeller
116
Siemens
118
Testing the Valves and Additional Outputs
121
Control System
123
Reaction During Faults
123
Short Circuit/Overload at the Additional Output
124
System Structure
131
Valve Terminal
132
Advertisement
Festo IIFB-02- Series Manual (123 pages)
Valve Terminal/Valve Sensor Terminal with Field Bus Connection
Brand:
Festo
| Category:
Touch terminals
| Size: 0 MB
Table of Contents
2. System Structure
11
System Structure
12
Valve Terminal
12
Valve Sensor Terminal
13
Valve Terminal/Valve Sensor Terminal in the Control System
14
3. Technical Description
19
Table of Contents
19
Technical Description
20
Structure
20
Valve Terminal
20
Valve Sensor Terminal
22
Function
25
Explanation on Function Summary
26
Technical Specifications
27
General
27
Electronic Components
28
RIO Link
30
Pneumatic Components
31
Connection Block
31
Valves
36
4.2 Installing the Pneumatic Components
41
Installing the Pneumatic Components
42
Laying the Hoses
43
General
43
Preparing the Connection Block
44
Connecting the Connection Block
45
Connecting the Valves
46
Solenoid Valve (5/2-Way)
47
Solenoid Pulse Valve (5/2-Way) and Solenoid MID-Position Valve (5/3-Way)
48
Checking the Valve Functions
49
Manual Overrride
49
Designs of Manual Override
50
Testing
51
Locking the Manual Override
53
4.3 Installing the Electronic Components
55
Installing the Electronic Components
56
Opening and Closing the RIO Node
58
Configuring the Valve Terminal/Valve Sensor Terminal
59
Address Selector Switch
60
Setting the RIO Address
60
Setting the RIO Baud Rate
63
Connecting the Valve Terminal/Valve Sensor Terminal
64
Connetcting the Cables to the Plugs/Sockets
64
24 V Operating Voltage Connection
66
Applying the 24V Operating Voltage
69
RIO Interface
72
RIO Cable
73
Connecting the RIO Interface
73
Fitting the Terminating Resistor
75
Outputs of Valve Locations
77
Additional Outputs
77
Pin Assignment Od Additional Outputs
78
Inputs
79
Pin Assignment of Sockets
80
Circuitry Examples
81
5. Commissioning
85
Commissioning
86
Configuring the Programmable Controller
86
Allen-Bradley
87
Switching on the Operating Voltage
88
Addressing the Inputs and Outputs
89
Valve Terminal
89
Valve Locations
89
Valve Sensor Terminal
91
Valve Locations, Inputs and Additional Outputs
91
Status Bits
94
Manufacturer-Specific Features
95
Allen-Bradley
95
6. Diagnosis and Error Treatment
105
Diagnosis and Error Treatment
106
LED Displays
106
RIO Node
106
Valves
108
Inputs and Additional Outputs
109
Testing the Valves and Additional
110
Diagnosis
110
Outputs
110
Reaction During Faults
114
Short Circuit/Overload at the Additional
115
Advertisement
Related Products
Festo IIFB-02-1/8-4
Festo IIFB-02-1/8-6
Festo IIFB-02-1/8-8
Festo IIFB-02-1/8-10
Festo IIFB-02-1/8-12
Festo IIFB-02-1/8-14
Festo IIFB-02-1/4-6
Festo IIFB-02-1/4-4
Festo IIFB-02-1/4-8
Festo IIFB-02-1/4-10
Festo Categories
Industrial Equipment
Control Unit
Controller
Touch terminals
DC Drives
More Festo Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL