Checking The Valve Functions; Manual Overrride - Festo VIFB-02- Series Manual

Valve terminal/valve sensor terminal with field bus connection
Hide thumbs Also See for VIFB-02- Series:
Table of Contents

Advertisement

VIFB1 – 02

Checking the valve functions

> IFB1-02_BES_V_018474g1_1996-04N - Restored Document - 2011-12-15 <
9604
4. Installation
Manual override
The manual override (see Fig. 4/7) is used prin-
cipally when the pneumatic system is commis-
sioned, as a means of checking the function and
effect of the valve or of the valve-cylinder combi-
nation. By operating the manual override, the
user can switch the valve without an electric sig-
nal. Only the compresssed air supply needs to
be switched on.
14
4
2
12
Fig. 4/7: Position of the manual override
Pilot valve
Manual override
Base valve
Manual override
Pilot valve
4-13