VIFB1 – 02
Connecting the valve terminal/valve sensor terminal
4-28
> IFB1-02_BES_V_018474g1_1996-04N - Restored Document - 2011-12-15 <
4. Installation
General
PLEASE NOTE
If one of the plugs is not used, it should be
sealed with a protective cap (protection
class IP65).
Connecting the cables to the plugs/sockets
1. Open the plugs/sockets as follows
(see following diagram):
• Power supply socket:
Insert the power supply socket into the
operating voltage plug on the valve
terminal/valve sensor terminal. Unscrew the
housing part of the socket. Now remove
the connection part of the socket from
the plug.
• Sensor socket (for field bus connection
and electrical inputs/outputs):
Unscrew the centre knurled nut.
• Bus cable socket (for field bus connection):
Unscrew the centre knurled nut.
2. Unscrew the stain relief part at the rear of
the housing.
Insert the cables as follows (see diagram):
Cable diameter:
•
power supply socket
•
sensor socket
Plugs/sockets (straight or angled):
•
power supply
•
sensor socket
•
bus cable socket
PG 7: 4.0 mm ... 6.0 mm
PG 9: 6.0 mm ... 8.0 mm
PG 13:10.0 mm ...12.0 mm
PG 7, 9 or 13.5
PG 7
PG 7, 9 or 13.5