4. Installation
Address selector switch
The field bus address of the valve terminal/valve
sensor terminal can be set with the two address
selector switches on board 2. The switches are
numbered from 0...9. The arrow on the address
selector switches indicates the tens and units fig-
ure of the field bus address which has been set.
UNITS
7 8
6
5
4
3
2
7 8
6
5
4
3
2
TENS
Fig. 4/14: Function of the address selector
switch
Setting the field bus address
PLEASE NOTE
Field bus addresses may only be assigned
once per field bus module.
Recommendation:
We recommend that the field bus addresses be
assigned in ascending order. Field bus addres-
ses should be assigned in accordance with the
machine structure of the system. The field bus
addresses set should be noted in the grey
inscription field above the field bus node.