VIFB8 – 02
9706
4. Installation

Connecting the valves

PLEASE NOTE
The non-reserved or free valve locations
should be protected with a cover plate.
If one of the fitted valves is not used,
connections 2 and 4 as well as 14 and,
if necessary, 12 must be covered with
blind plugs.
The seals used on connections 2 and 4
should be of aluminium.
Proceed as follows:
Remove the lupolen plugs and fit the screw con-
nectors with the appropriate seals as indicated
in the following tables:
Fig. 4/5: Pin assignment of solenoid valve
Fig. 4/6: Pin assignment of solenoid pulse valve
and solenoid mid-position valve
The hoses should then be fitted into place.
PLEASE NOTE
The work connections 2 and 4 are situated in
different positions on the various types of val-
ves (see also next page).
4-11