VIFB1 – 02
Addressing the inputs/outputs
> IFB1-02_BES_V_018474g1_1996-04N - Restored Document - 2011-12-15 <
9604
5. Commissioning

Valve terminal

The outputs (valve locations) are addressed with
one or two output words depending on the size
of the valve terminal.
Valve terminal type 02
up to 8 valve locations
more than 8 valve
locations
more than 8 valve
locations
Fig. 5/4: Number of output words to be
addressed

Valve locations

Each valve location has two outputs. The desig-
nation of these outputs is noted on the valve ter-
minal and is composed as follows:
Designation for
Output
O 1 . 05
Bit no. in output word
Output word no.
Fig. 5/5: Composition of designation
for output word
Output words to be addressed
1
2
2
Output
5-9